  1. Thread: Holidays

    by Sparky51
    Replies
    3
    Views
    453

    Re: Holidays

    To all of the experts who help all of us rookies. The knowledge, expertise, and guidance that you give all of us throughout the year are gifts that can never be adequately repaid. Thank You and...
  2. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    Thank you to all!
    And to all, have a very Happy Holiday!
  3. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    Installed 1.0x60 nozzle + new t-stat. Bingo, problem fixed! Also, heard from Olsen. They said I can go down to a .85x80 nozzle if I need to and change speeds at fan center (not on motor). I...
  4. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    Just did some calculations about my ducts. My old system had about 374 square inches of heat duct and 384 square inches of return air. The new system has 226 square inches of heat and 112square...
  5. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    If I'm reading all this correctly (and my head's swimming pretty good), it sounds like the thoughts are that I have an oversize furnace and undersize ducting.
    Haven't heard from Olsen yet about...
  6. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    My screw up--the blower doesn’t shut down at high limit, the burner does. Sorry for the confusion.

    Crawled into the blower compartment and found the motor tag (pretty well hidden) Model 10-DD. ...
  7. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    The manual shows a 4 speed blower motor and talks about changing the speed. I just can't see how to do it since the wiring diagram doesn't look like the actual blower wiring. Also not sure what...
  8. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    OK, here are today’s changes.
    1. I have an old mercury t-stat, and I don't see any contacts. So, I'm guessing that tip won’t fly for me. I'd prefer not to take it down to run the furnace...
  9. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    And right now, I need al the luck I can get. :)
  10. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    Hi Sten,
    Posted my reply before your last post came in. What a great idea! Have to leave right now, but will try that soon as I get back. Thanks! Gary
  11. Replies
    30
    Views
    64,537

    Re: Forced air furnace burner short cycling

    ***! Thanks to all who've responded so far.

    I'll try everything suggested so far, one by one, and hopefully something will work. My serviceman keeps saying it's the limit switch settings, but...
  12. Replies
    30
    Views
    64,537

    Forced air furnace burner short cycling

    We have a 2 year old Olsen BCL145S furnace. installed in the basement of our 90 y/o, 1300 sq. ft. house. During a heat cycle, the burner cycles on/off 2 or 3 times; the blower sems to cycles...