Search:

Type: Posts; User: gwilkrrs

Page 1 of 4 1 2 3 4

Search: Search took 0.05 seconds.

  1. Re: bringing a bathroom subfloor up to the proper height

    so I am moving slowly on this project- the wood floors are now complete. the finished floor is 1 1/2" higher then the slab as suspected. the tiles are a touch thicker then 1/8" he said (1" hexagon...
  2. Replies
    9
    Views
    13,067

    Re: knotty pine wood primer?

    I ran it thru the sprayer so I had to flush that....... label said equal parts water to ammonia
  3. Replies
    9
    Views
    13,067

    Re: knotty pine wood primer?

    good tip cause bin said ammonia and I didn't have any of that!
  4. Replies
    9
    Views
    13,067

    Re: knotty pine wood primer?

    thanks for the replies... I will look for the BIN primer to be done in 1 step, I do not want to dealing again in a year
  5. Replies
    9
    Views
    13,067

    knotty pine wood primer?

    i am close to painting on my addition, I will be painting my ceilings that are constructed out of 1x8 v groove wood. it is a pine product with knots. what is the process and materials for priming and...
  6. Replies
    12
    Views
    2,547

    Re: hard wiring smoke detector question

    not run in conduit
  7. Re: how to feed another switch from a switch question

    looks like I will pull a feed up from the receptacle below the switch for the outside light.....................
  8. Replies
    12
    Views
    2,547

    Re: hard wiring smoke detector question

    so it took 5 hours but we managed to pull a solid single wire thru to the fixtures- from 1 to 2 and 2 to 3......
  9. Re: how to feed another switch from a switch question

    ok- so here it is........................
    got it on above box feed here is the next delema. so the final box with the 4 way switch I am trying to get a feed out of for an outside light...... so I...
  10. Re: how to feed another switch from a switch question

    THANKS! I will try this
  11. Re: how to feed another switch from a switch question

    gotcha- are any wires on the 3 way constant hot?
    this is a middle run box...
    feed comes into first box has this 3 way and a 4 way, then this box has the 3way a 4 way and a single then this 3way...
  12. how to feed another switch from a switch question

    I have 3 switch box. 1 switch is a 3way, 1 switch is a 4way, 1 switch is a single pole. I need to take a feed from either the 4 way or 3 way to feed the single pole and another single pole in the box...
  13. Replies
    12
    Views
    2,547

    Re: hard wiring smoke detector question

    stink................. that's what I thought.
  14. Replies
    12
    Views
    2,547

    Re: hard wiring smoke detector question

    feed to first box= 2 wire
    box 1 to box 2= 3 wire
    box 2 to box 3= 2wire
    box 3 to box4= 2 wire

    no wireless devices......
  15. Re: finish floor is 1 1/2" above slab for bathroom

    awesome- thanks!
    what steps would you use?
    does it still need a thermal break?

    I need her to pick out tile to verify thickness but I plan to work backwards from tile +thinset thickness and heat...
  16. Replies
    12
    Views
    2,547

    hard wiring smoke detector question

    so I have 4 wired smoke detectors to install. the rough ins are complete but I think he made a mistake. there is 2 wire (black/white/ground) going to the first box, 3 wire going from the first box to...
  17. Re: finish floor is 1 1/2" above slab for bathroom

    let me be more clear- I planned for the 1 1/2" diference. I have a plan for the wood side, and I set all fixtures at the 1 1/2" raised height for finish floor on the bath side so there isn't a worry...
  18. Re: finish floor is 1 1/2" above slab for bathroom

    no nothing exotic- select red oak 3/4" thick on top of 3/4" plywood on top of the slab for a total of 1 1/2"
  19. Re: finish floor is 1 1/2" above slab for bathroom

    thanks for the lead!
  20. finish floor is 1 1/2" above slab for bathroom

    so my slab was poured all the same height for living room and bathroom. the living room floor gets 3/4" and 3/4" (1 1/2") on top of the slab to finish. I am putting tile in the bathroom and...
  21. Re: concrete subfloor- 3/4" hardwood install questions

    ok- I hadn't thought about PT.
    I asked local flooring guys and got all differsnt answers...............
  22. Re: concrete subfloor- 3/4" hardwood install questions

    no room for sleepers- subfloor is set down 1-1/2" 3/4 for plywood and 3/4 for flooring.

    I planned on the poly but think the fasteners thru the plywood into the slab will negate the effects of...
  23. concrete subfloor- 3/4" hardwood install questions

    so I have an addition I will be putting 3/4" red oak flooring in. the subfloor is slab on grade, it has 6mil poly under the slab and was poured a year ago. I will be putting 3/4" plywood over the...
  24. Replies
    1
    Views
    198

    pergola framing ?

    i am planning on adding brackets on the end wall of my addition that stick out 3' and creating a pergola roof to block some sun. I didn't want to run tall header beams but maybe a double or triple...
  25. Re: bringing a bathroom subfloor up to the proper height

    sleepers would put the top of the sleeper at finish floor height- i only have 1-1/2" total from slab to top of finished tile work- i am guessing 3/8" to 1/4" for the tile and 3/8" for the setting...
Results 1 to 25 of 81