    Re: Prep for backup generator

    Check out this link to Generac sold at HD as Guardian. Open the first brochure, and the 2nd page has a great sizing sheet. That' s what we use to size them.
    ...
  2. Replies
    5
    Views
    828

    Re: Whole House Surge Supression

    PUT IT IN. For complte protecion you need protection at the service entrance, and a high quality point of use surge strip / outlet. For a few hundred bucks you can protect thousands in electronics....
  3. Replies
    13
    Views
    20,538

    Re: Wiring shed with 10-3 wire

    no, if you are using 10/3 you have 2 hot's a neutral, and a ground. You are grounding this panel via the main panel
  4. Re: Pulling a new line from basement to second floor

    try to chase next to the chiminey or pipe it outside in pvc
  5. Replies
    13
    Views
    20,538

    Re: Wiring shed with 10-3 wire

    sleeve it in pvc, then use a 2p 30a breaker to feed a sub panel (4 or 8 ckt)
  6. Replies
    8
    Views
    12,594

    Re: Old-stye electrical box

    if you are uncomforable replacing the Box, call an ELECTRICIAN, a few hundred bucks now will save you big down the road. Is the pendant light low voltage? if so it will have a transformer that...
  7. Thread: gfci bad?

    by mike_g
    Replies
    5
    Views
    855

    Re: gfci bad?

    Breakers fail. Some more than others What brand panel do you have?
  8. Replies
    6
    Views
    1,122

    Re: GFCI installation

    Personally i would use a GFCI receptacle rather than breaker. When it trips you can reset it more easily, it's about 1/3 to 1/2 the cost of a breaker, and it will protect all devices 'down stream'...
  9. Replies
    10
    Views
    37,562

    Re: Ceiling Fan Hoist or Lift System

    isn't there a safety cable that runs from the fan, through the down rod, to the ball joint, which is 'permantly' mounted to a fan rated electrical box?
  10. Replies
    4
    Views
    8,690

    Re: Installing Range Vent and Bathroom Vents

    1)When running duct, use the staightest path possible as every bend adds static pressure, lowering the CFM (air movement). 2)you can use flexible metal duct. 3)Ducting out the eve is common, it...
  11. Replies
    10
    Views
    37,562

    Re: Ceiling Fan Hoist or Lift System

    it would be a code violation, fans need to permanatly attached
  12. Replies
    9
    Views
    2,727

    Re: Installing an outlet in a vanity

    Just a note on the above, they (arlington, smart box, and allied molded) make a pvc box with screw already installed on the inside. And pancake box is ok for a pendent as you can count the cubes in...