  1. Replies
    3
    Views
    1,604

    Re: Pin hole leaks in hot water pipes in slab

    <object width="500" height="405"><param name="movie" value="http://www.youtube-nocookie.com/v/LXBU4T0q64A&hl=en_US&fs=1&border=1"></param><param name="allowFullScreen" value="true"></param><param...
  2. Replies
    69
    Views
    25,947

    Re: pin hole leaks in copper pipe

    lol copper tube is antibaterial and builds a nautural protective film inside the tube.Most pinhole copper jobs i get called to are caused by excess oil based flux preventing patina adhesion from...
  3. Replies
    4
    Views
    1,448

    Re: waste pipe for toilet

    it is 6' on three inch to vent or 10'for four inch you will need to vent tis fixture either way and back vent it back to the stack or other properly sized vents to meet most plumbing requirments and...
  4. Thread: Howling Pipes

    by djrenek1
    Replies
    7
    Views
    1,542

    Poll: Re: Howling Pipes

    what type of system staple up thermoboards etc? is this noise coming from the manifolds supply and return piping and what material was used for supply and return? pex or copper ? this sounds like...
  5. Replies
    3
    Views
    1,530

    Re: Hot mixing with cold water in Bathroom

    a new shower cartridge should remedy the situtation
  6. Replies
    3
    Views
    1,473

    Re: Removing lime scale from CI pipes

    oh my lord!! dont ever put any chemicals into your potable water suppy you are endangering the life of your family and your neighbors a neg pressure drop in the line and bam you just poisoned your...
  7. Replies
    6
    Views
    1,169

    Re: Replaced Cast Iron (CI) with ABS - NOISE!

    repipe in cast lol
  8. Replies
    19
    Views
    123,085

    Re: Copper vs CPVC vs Pex - which to use?

    COPPER!!! stay away from the garden hose lol
  9. Thread: old tub drain

    by djrenek1
    Replies
    1
    Views
    707

    Re: old tub drain

    sure! you can buy waste and overflows at the supply house.. i've put modern w/o's on CI tubs from the early 1900's no problem
  10. Replies
    1
    Views
    909

    Re: Rusted galvanized pipe connection

    go to the local plumbing supply and but a nut buster
  11. Thread: no hot water

    by djrenek1
    Replies
    2
    Views
    605

    Re: no hot water

    this is a gas water heater right?? did you light the burner or does it fire? no water flow from hot side of fixtures? check the factory heat trap nipple on the hot side of the heater they have little...
  12. Replies
    69
    Views
    25,947

    Re: pin hole leaks in copper pipe

    buncha hacks on here
  13. Replies
    8
    Views
    1,705

    Re: house pipes have water leak

    i know of a skilled licensed plumbing contractor in central fl.
    he specializes in slab leaks and re-pipes he your man look up protech plumbing..
  14. Re: radient floor heat and tankless water heater

    also look into combi style boilers basically a boiler that runs heating zones on one side and a tankless exchanger with buffer tank built in on the other side.
  15. Re: radient floor heat and tankless water heater

    you need to consult a local plumbing heating contractor.. i will tell you though tankless is a bad option for domestic and radiant.. i'd say a mod con bolier with a indirect tank with air handler..
  16. Replies
    69
    Views
    25,947

    Re: pin hole leaks in copper pipe

    "hogwash" huh..? lol you have to look at the facts in this case.. to any "plumber" this should be clearly obvious. you are generally right about velocity erosion due to unreamed joints taking time to...
  17. Replies
    69
    Views
    25,947

    Re: pin hole leaks in copper pipe

    your problem was a combonation of a circulator with no timer/ thermostat (plugged in running 24/7) and unreamed tubing:eek: and most likely exessive oil based flux your lucky the leak was right at...
  18. Replies
    2
    Views
    815

    Re: Joining vents running downhill?

    waste vents cant run downhill hill period!
  19. Thread: Noisy PRV

    by djrenek1
    Replies
    5
    Views
    4,045

    Re: Noisy PRV

    i say new prv
    - sean the plumber
  20. Replies
    5
    Views
    16,338

    Re: Connecting to cast iron pipes

    oakum and lead wool packed is good for horizontal joints
  21. Re: New PVC piping attached to old broken copper pipebath fixtures...help!

    why on earth would you wanna replace copper tube with plastic crap..?:eek: are you saying that plastic is glued straight to copper tube..?
  22. Replies
    5
    Views
    3,879

    Re: PVC to replace galvanized

    USE COPPER! but if you are gonna go cheap you use cpvc for potable.. not regular pvc
  23. Replies
    3
    Views
    2,260

    Re: rattling pipes

    make sure your pipes are st****d properly..
  24. Replies
    26
    Views
    9,599

    Re: Toilet installation in basement

    i think you got it backwards.. the maximum distance to water closet trap arm to vent is 6 feet. upc requires 15" clear on each side of w/c. make sure its 12" from FINISHED wall.. you still need...
  25. Thread: Attic tank

    by djrenek1
    Replies
    8
    Views
    1,193

    Re: Attic tank

    anyting roughed in in the 1800's is not to code sorry! you cant even make it work with modern water closets